Aircon Services
Aircon Installers Johannesburg Aircon Installation Aircon Repairs Aircon Service Aircon Regas Aircon Maintenance Aircon Cleaning
Problems & Replacement
Aircon Not Cooling Aircon Leak Repair Aircon Replacement Aircon Relocation
System Types
Split Unit Installation Inverter Installation Multi Split Installation Cassette Installation Ceiling Installation Ducted Air Conditioning VRF Air Conditioning
Residential & Commercial
Residential Air Conditioning Commercial Air Conditioning Aircon Supply and Installation Apartment Installation Body Corporate Installation
Property Types
Office Air Conditioning Shop Air Conditioning Restaurant Air Conditioning Warehouse Air Conditioning Industrial Air Conditioning Server Room Air Conditioning
HVAC & Ventilation
HVAC Contractors HVAC Installation HVAC Maintenance Ventilation Installation Bathroom & Toilet Ventilation Smoke Ventilation Core Drilling
Prices
Aircon Prices Johannesburg
Areas – Regions
East Rand Johannesburg South
Areas – Sandton & Surrounds
Sandton Bryanston Morningside Rivonia Sunninghill Woodmead Illovo Hyde Park Rosebank
Areas – Midrand & Far North
Midrand Kyalami Fourways North Riding
Areas – Randburg & Northcliff
Randburg Ferndale Northcliff Honeydew Weltevredenpark Melville
Areas – West Rand
Roodepoort Krugersdorp
Areas – East Rand Suburbs
Bedfordview Edenvale Kempton Park Germiston Boksburg Benoni Springs Alberton
Areas – Central & South
Houghton Rosettenville
Company
Reviews About Contact

Bathroom & Toilet Ventilation Installers Johannesburg

Get the best quote, fast
5-Star Reviewed
Home Bathroom & Toilet Ventilation

Bathroom and toilet extraction removes moisture and odour at the point it is created, before it gets into the rest of the house. It is a small job with an outsized effect: most of the mould, peeling paint, blistered cornices and damp ceiling boards blamed on rising damp in Johannesburg houses is a shower running into a room with nowhere for the vapour to go.

Describe the bathroom and what is there now, and get extraction quotes.

Get Extraction Quotes

What an Extractor Fan Actually Has to Do

Two jobs, and they are not the same. Odour removal in a toilet is a modest, intermittent duty that almost any fan handles. Moisture removal in a shower room is a real load: a hot shower puts a surprising amount of water vapour into the air in a few minutes, and unless it is taken outside it condenses on the coldest surface in the house.

That surface is rarely in the bathroom. Vapour migrates, so it tends to appear as mould in a corner of an adjoining bedroom, on the inside of an outside wall, or in the roof void above the ceiling. People then treat the symptom where it shows rather than the cause where it starts.

The practical consequence is that the fan has to run long enough to clear the moisture, not just long enough for someone to finish showering. A fan wired to the light switch stops the moment the light goes off, which is usually well before the room is clear.

Venting Into the Roof Void Is the Fault We See Most

An extractor fan has to discharge outside the building. A very large number of Johannesburg installations do not: the fan sits in the ceiling, the flexible duct runs a metre into the roof void, and it stops there, or it was never connected at all. The room clears, so the owner assumes it works.

What is actually happening is that warm, wet air is being pumped into the roof space, where it condenses on the underside of the sheeting or tiles and on the roof timbers. Over a few seasons that produces mould on the trusses, stained and sagging ceiling boards, and in bad cases rot in the timber. It is a far more expensive problem than the fan that caused it.

The fix is the same work done properly: rigid or semi-rigid duct, as short and straight as the layout allows, taken to a wall cowl, a gable vent or a roof tile vent with a backdraught shutter on it. Where the duct crosses a cold roof void in winter it wants insulating, otherwise condensation forms inside the duct and runs back down into the fan.

If you have a bathroom fan and have never seen where it comes out on the outside of the building, it is worth checking. Re-routing an existing fan to discharge outside typically runs R1,800 to R4,500, against ceiling and truss repairs that run into tens of thousands.

Sizing, Ducting and Make-Up Air

Sizing is usually expressed either as a flow rate or as air changes per hour. A domestic bathroom is commonly specified around 15 litres per second, a separate toilet rather less, and a shower room used heavily or a commercial washroom noticeably more. What matters more than the headline number is whether the fan can achieve it against the duct it is connected to.

This is where most underperforming installations go wrong. A small axial fan is designed to push air through a short, straight duct. Give it five metres of concertinaed flexible ducting with two tight bends and it will spin happily while moving very little air. For anything but a short run straight out through the wall behind it, an inline centrifugal fan mounted in the roof void is the better choice, and it is quieter in the room as well because the motor is not above your head.

Make-up air is the half everyone forgets. A fan cannot extract air from a sealed room. If the door is well fitted and closed, the fan has nothing to draw in and the flow collapses. A ten millimetre undercut on the door, or a transfer grille, is what lets it work at all. Where a bathroom fan seems weak, this is worth checking before anyone replaces the fan.

Controls: Timer, Humidistat or Switch

A plain fan on the light switch is the cheapest arrangement and the least effective, because it runs only while somebody is in the room. A timer overrun keeps it going for a set period after the light goes off, which covers the period when the room is actually clearing. Fifteen to twenty minutes is typical.

A humidistat is better again for a shower room, because it responds to the actual moisture level rather than to a clock: it runs until the room is dry and then stops, which means it neither cuts out early on a long shower nor runs pointlessly on a dry day. For a toilet used for odour control, a timer or a simple switch is fine and a humidistat is wasted money.

On the electrical side, a bathroom fan is subject to the wiring regulations covering the zones around a bath or shower, which affects the IP rating the fan must have and where the isolator can be placed. The isolator generally sits outside the room. This is an electrician’s call rather than a guess, and it is part of why a fan swap is not quite the ten-minute job it looks like.

Older Houses, Complexes and Apartment Blocks

Johannesburg’s older stock throws up a specific version of this problem. In the 1930s to 1950s housing around Melville, Houghton, Rosettenville and the older East Rand suburbs, bathrooms were built with an openable window and no fan. Where a later addition, an enclosed stoep or a converted outbuilding has left a bathroom internal, mechanical extraction stops being optional and the walls are solid, so the duct route needs core drilling rather than a hole saw.

In townhouse complexes and sectional title blocks the constraint is different again. The external wall or the roof is usually common property, so a new discharge point needs body corporate approval, and in many blocks the bathrooms already discharge into a shared riser or shaft. Where individual fans feed a common shaft without backdraught shutters, one flat’s extract becomes the next flat’s supply, which is the usual explanation for smelling a neighbour’s bathroom in your own. Fitting shutters is cheap; diagnosing it as a shaft problem rather than a fan problem is the part that takes someone who has seen it before.

Guesthouses and small hotels, which Johannesburg has a lot of around the airport, are on a heavier duty again: every en-suite running several times a day, and a smell or a mould mark is a review. Those want commercial-grade fans and a service interval rather than fit-and-forget.

Bathroom and Toilet Extraction Prices in Johannesburg

Indicative ranges, supplied and fitted. Useful for sanity-checking a quote rather than as a quotation.

ScopeIndicative rangeNotes
Axial fan replaced, existing duct reusedR1,200 – R2,800Like-for-like swap
New bathroom fan, ducted through an outside wallR2,500 – R5,500Short straight run
Inline roof-void fan, ducting and ceiling grilleR3,500 – R8,500Quieter, handles longer runs
Separate toilet, small axial fanR1,000 – R2,400Odour duty rather than moisture
Re-routing a fan that vents into the roof voidR1,800 – R4,500The most common remedial job
Timer overrun controlR350 – R800Runs on after the light goes off
Humidistat controlR550 – R1,500Better for showers than a timer
Insulated ductingR250 – R550 per metreStops condensation forming in the duct
Core drill through brick or concreteR650 – R2,200Solid walls and slabs
Wall cowl or roof vent with backdraught shutterR450 – R1,400Keeps weather and insects out
Door transfer grille or undercutR250 – R900Make-up air, without which flow collapses
Dedicated circuit and isolatorR1,800 – R5,500Where the board has no spare way
Body corporate applicationR0 – R2,500New discharge points on common property
Apartment block riser fan, commercialR18,000 – R75,000Central roof-mounted extract

Indicative ranges, not a quotation. The duct route is what moves the number. A fan on an outside wall with a straight run behind it is at the bottom of these ranges; the same fan in an internal bathroom needing an inline unit, a ducted route across a roof void and a core drilled discharge is at the top.

Get the actual number for your bathroom from local contractors.

Get Extraction Quotes

Frequently Asked Questions

Does a bathroom extractor fan have to vent outside?

Yes. Discharging into the roof void simply moves the moisture from a room you can see into a space you cannot, where it condenses on the roof timbers and the back of the ceiling. It is the single most common fault we see, and it causes mould on trusses, stained and sagging ceilings and eventually rot. The duct has to terminate at a wall cowl, a gable vent or a roof vent, with a backdraught shutter on the outlet.

Am I required to have mechanical extraction in a bathroom?

The national building regulations deal with ventilation of rooms like bathrooms and toilets, and the general principle is that a room needs either adequate natural ventilation, usually an openable window or opening of a certain size relative to the floor area, or mechanical ventilation in its place. A bathroom with no openable window therefore needs a fan. Where a plan is being submitted or a property is being signed off, the requirement is worth confirming with whoever is handling the approval, since it is driven by the room and the building rather than by a single blanket rule.

My fan runs but the mirror still steams up. What is wrong?

Usually one of three things, and replacing the fan is rarely the answer. Most often there is no make-up air, because a well-fitted closed door leaves the fan nothing to draw in, and a ten millimetre undercut fixes it. Second most common is duct resistance: a small axial fan connected to several metres of concertinaed flexible ducting with tight bends moves very little air regardless of its rating. Third is a blocked or seized backdraught shutter at the outlet. Have those checked before buying anything.

What size fan does a bathroom need?

A domestic bathroom is commonly specified around 15 litres per second, with a separate toilet lower and a heavily used shower room or commercial washroom higher. The more useful question is what the fan can actually deliver against your duct run, since a fan rated for a figure in free air will fall well short of it through five metres of flexible duct. For anything other than a short straight run through the wall behind the fan, an inline centrifugal unit in the roof void is the better choice.

Timer or humidistat?

For a shower room, a humidistat, because it runs until the room is actually dry rather than for a fixed period that may be too short on a long shower and pointless on a dry day. For a toilet where the duty is odour rather than moisture, a timer overrun of fifteen to twenty minutes is fine and a humidistat is money you do not need to spend. What you want to avoid in a shower room is a fan wired straight to the light, which stops well before the room has cleared.

We can smell the neighbours’ bathroom in our flat. Is that our fan?

Usually not. In blocks where individual bathrooms discharge into a shared riser or shaft, air can pass back down into other units, particularly where the original backdraught shutters have seized or were never fitted. The fix is shutters on the individual outlets and, in some blocks, a properly working central extract fan at the head of the shaft. It is worth raising with the body corporate rather than replacing your own fan, since the shaft is common property and the problem is rarely confined to one flat.

Related Aircon Services

Aircon Installers Johannesburg is a free quote-matching service. We do not install, repair or service air conditioners ourselves. Every quote comes from a LEADERR APPROVED local contractor, and your contract is with the business you appoint. Assess each quote on its own merits before appointing anyone.

Describe the job once and compare quotes from LEADERR APPROVED contractors in your area.

Get 5 Quotes

Get Bathroom Extraction Quotes

Tell us the room, whether there is an openable window, and where the duct can run.

Free to use, no obligation. Your request goes to LEADERR APPROVED contractors covering your area, who quote you directly.